"comment": "This is a sample configuration for EOS versions above 4.20",
|
|
"subscriptions": [
|
|
"/Smash/counters/ethIntf",
|
|
"/Smash/interface/counter/lag/current/counter",
|
|
|
|
"/Sysdb/environment/archer/cooling/status",
|
|
"/Sysdb/environment/archer/power/status",
|
|
"/Sysdb/environment/archer/temperature/status",
|
|
|
|
"/Sysdb/hardware/archer/xcvr/status"
|
|
],
|
|
"metricPrefix": "eos",
|
|
"metrics": {
|
|
"intfCounter": {
|
|
"path": "/Smash/counters/ethIntf/FocalPointV2/current/(counter)/(?P<intf>.+)/statistics/(?P<direction>(?:in|out))(Octets|Errors|Discards)"
|
|
},
|
|
"intfLagCounter": {
|
|
"path": "/Smash/interface/counter/lag/current/(counter)/(?P<intf>.+)/statistics/(?P<direction>(?:in|out))(Octets|Errors|Discards)"
|
|
},
|
|
"intfPktCounter": {
|
|
"path": "/Smash/counters/ethIntf/FocalPointV2/current/(counter)/(?P<intf>.+)/statistics/(?P<direction>(?:in|out))(?P<type>(?:Ucast|Multicast|Broadcast))(Pkt)"
|
|
},
|
|
"intfLagPktCounter": {
|
|
"path": "/Smash/interface/counter/lag/current/(counter)/(?P<intf>.+)/statistics/(?P<direction>(?:in|out))(?P<type>(?:Ucast|Multicast|Broadcast))(Pkt)"
|
|
},
|
|
"intfPfcClassCounter": {
|
|
"path": "/Smash/counters/ethIntf/FocalPointV2/current/(counter)/(?P<intf>.+)/ethStatistics/(?P<direction>(?:in|out))(PfcClassFrames)"
|
|
},
|
|
|
|
"tempSensor": {
|
|
"path": "/Sysdb/(environment)/archer/temperature/status/(?P<sensor>.+)/((?:maxT|t)emperature)"
|
|
},
|
|
"tempSensorAlert": {
|
|
"path": "/Sysdb/(environment)/archer/temperature/status/(?P<sensor>.+)/(alertRaisedCount)"
|
|
},
|
|
"currentSensor": {
|
|
"path": "/Sysdb/(environment)/archer/power/status/currentSensor/(?P<sensor>.+)/(current)"
|
|
},
|
|
"powerSensor": {
|
|
"path": "/Sysdb/(environment)/archer/(power)/status/powerSupply/(?P<sensor>.+)/(input|output)Power"
|
|
},
|
|
"voltageSensor": {
|
|
"path": "/Sysdb/(environment)/archer/power/status/voltageSensor/(?:cell/.+|system)/(?P<sensor>.+)/(voltage)"
|
|
},
|
|
"railCurrentSensor": {
|
|
"path": "/Sysdb/(environment)/archer/power/status/voltageSensor/(?:cell/.+|system)/(?P<sensor>.+)/(current)"
|
|
},
|
|
"fanSpeed": {
|
|
"path": "/Sysdb/(environment)/archer/(cooling)/status/(?P<fan>.+)/speed"
|
|
},
|
|
|
|
"qsfpModularRxPower": {
|
|
"path": "/Sysdb/hardware/archer/(xcvr)/status/slice/(?P<linecard>.+)/(?P<intf>.+)/domRegisterData/lane(?P<lane>\\d)(OpticalRxPower)"
|
|
},
|
|
"qsfpFixedRxPower": {
|
|
"path": "/Sysdb/hardware/archer/(xcvr)/status/all/(?P<intf>.+)/domRegisterData/lane(?P<lane>\\d)(OpticalRxPower)"
|
|
},
|
|
"sfpModularTemperature": {
|
|
"path": "/Sysdb/hardware/archer/(xcvr)/status/slice/(?P<linecard>.+)/(?P<intf>.+)/lastDomUpdateTime/(temperature)"
|
|
},
|
|
"sfpFixedTemperature": {
|
|
"path": "/Sysdb/hardware/archer/(xcvr)/status/all/(?P<intf>.+)/lastDomUpdateTime/(temperature)"
|
|
}
|
|
}
|
|
}
|