ipld-eth-server/vendor/github.com/btcsuite/btcd/log.go
Matt K 293dd2e848 Add vendor dir (#16) (#4)
* Add vendor dir so builds dont require dep

* Pin specific version go-eth version
2018-01-29 13:44:18 -06:00

169 lines
4.9 KiB
Go

// Copyright (c) 2013-2017 The btcsuite developers
// Copyright (c) 2017 The Decred developers
// Use of this source code is governed by an ISC
// license that can be found in the LICENSE file.
package main
import (
"fmt"
"os"
"path/filepath"
"github.com/btcsuite/btcd/addrmgr"
"github.com/btcsuite/btcd/blockchain"
"github.com/btcsuite/btcd/blockchain/indexers"
"github.com/btcsuite/btcd/connmgr"
"github.com/btcsuite/btcd/database"
"github.com/btcsuite/btcd/mempool"
"github.com/btcsuite/btcd/mining"
"github.com/btcsuite/btcd/mining/cpuminer"
"github.com/btcsuite/btcd/netsync"
"github.com/btcsuite/btcd/peer"
"github.com/btcsuite/btcd/txscript"
"github.com/btcsuite/btclog"
"github.com/jrick/logrotate/rotator"
)
// logWriter implements an io.Writer that outputs to both standard output and
// the write-end pipe of an initialized log rotator.
type logWriter struct{}
func (logWriter) Write(p []byte) (n int, err error) {
os.Stdout.Write(p)
logRotator.Write(p)
return len(p), nil
}
// Loggers per subsystem. A single backend logger is created and all subsytem
// loggers created from it will write to the backend. When adding new
// subsystems, add the subsystem logger variable here and to the
// subsystemLoggers map.
//
// Loggers can not be used before the log rotator has been initialized with a
// log file. This must be performed early during application startup by calling
// initLogRotator.
var (
// backendLog is the logging backend used to create all subsystem loggers.
// The backend must not be used before the log rotator has been initialized,
// or data races and/or nil pointer dereferences will occur.
backendLog = btclog.NewBackend(logWriter{})
// logRotator is one of the logging outputs. It should be closed on
// application shutdown.
logRotator *rotator.Rotator
adxrLog = backendLog.Logger("ADXR")
amgrLog = backendLog.Logger("AMGR")
cmgrLog = backendLog.Logger("CMGR")
bcdbLog = backendLog.Logger("BCDB")
btcdLog = backendLog.Logger("BTCD")
chanLog = backendLog.Logger("CHAN")
discLog = backendLog.Logger("DISC")
indxLog = backendLog.Logger("INDX")
minrLog = backendLog.Logger("MINR")
peerLog = backendLog.Logger("PEER")
rpcsLog = backendLog.Logger("RPCS")
scrpLog = backendLog.Logger("SCRP")
srvrLog = backendLog.Logger("SRVR")
syncLog = backendLog.Logger("SYNC")
txmpLog = backendLog.Logger("TXMP")
)
// Initialize package-global logger variables.
func init() {
addrmgr.UseLogger(amgrLog)
connmgr.UseLogger(cmgrLog)
database.UseLogger(bcdbLog)
blockchain.UseLogger(chanLog)
indexers.UseLogger(indxLog)
mining.UseLogger(minrLog)
cpuminer.UseLogger(minrLog)
peer.UseLogger(peerLog)
txscript.UseLogger(scrpLog)
netsync.UseLogger(syncLog)
mempool.UseLogger(txmpLog)
}
// subsystemLoggers maps each subsystem identifier to its associated logger.
var subsystemLoggers = map[string]btclog.Logger{
"ADXR": adxrLog,
"AMGR": amgrLog,
"CMGR": cmgrLog,
"BCDB": bcdbLog,
"BTCD": btcdLog,
"CHAN": chanLog,
"DISC": discLog,
"INDX": indxLog,
"MINR": minrLog,
"PEER": peerLog,
"RPCS": rpcsLog,
"SCRP": scrpLog,
"SRVR": srvrLog,
"SYNC": syncLog,
"TXMP": txmpLog,
}
// initLogRotator initializes the logging rotater to write logs to logFile and
// create roll files in the same directory. It must be called before the
// package-global log rotater variables are used.
func initLogRotator(logFile string) {
logDir, _ := filepath.Split(logFile)
err := os.MkdirAll(logDir, 0700)
if err != nil {
fmt.Fprintf(os.Stderr, "failed to create log directory: %v\n", err)
os.Exit(1)
}
r, err := rotator.New(logFile, 10*1024, false, 3)
if err != nil {
fmt.Fprintf(os.Stderr, "failed to create file rotator: %v\n", err)
os.Exit(1)
}
logRotator = r
}
// setLogLevel sets the logging level for provided subsystem. Invalid
// subsystems are ignored. Uninitialized subsystems are dynamically created as
// needed.
func setLogLevel(subsystemID string, logLevel string) {
// Ignore invalid subsystems.
logger, ok := subsystemLoggers[subsystemID]
if !ok {
return
}
// Defaults to info if the log level is invalid.
level, _ := btclog.LevelFromString(logLevel)
logger.SetLevel(level)
}
// setLogLevels sets the log level for all subsystem loggers to the passed
// level. It also dynamically creates the subsystem loggers as needed, so it
// can be used to initialize the logging system.
func setLogLevels(logLevel string) {
// Configure all sub-systems with the new logging level. Dynamically
// create loggers as needed.
for subsystemID := range subsystemLoggers {
setLogLevel(subsystemID, logLevel)
}
}
// directionString is a helper function that returns a string that represents
// the direction of a connection (inbound or outbound).
func directionString(inbound bool) string {
if inbound {
return "inbound"
}
return "outbound"
}
// pickNoun returns the singular or plural form of a noun depending
// on the count n.
func pickNoun(n uint64, singular, plural string) string {
if n == 1 {
return singular
}
return plural
}